What this tool does

Converts net target depth into a transparent gross application and cycle-and-soak schedule.

When to use it

Use after confirming precipitation rate and observing infiltration/runoff.

Inputs and supported units

Each labelled field explains the quantity it expects. Unit-system changes convert existing numeric entries once and keep calculations on a single SI internal basis. Supported shared units include L/min and GPM, metres and feet, kPa and psi, millimetres and inches, kW and hp, and °C and °F as relevant.

Calculation or decision method

Gross depth = net target / efficiency; runtime = gross depth / precipitation rate

How to interpret the result

Read the primary result with the supporting breakdown and warning. A plausible number is not evidence that every input, operating case or design constraint has been included.

Worked example

20 mm net at 80% efficiency and 10 mm/h needs 25 mm gross and 150 minutes.

Assumptions

Entered measurements represent the same operating condition. Calculations use unrounded SI values and convert only for display.

Limitations

This is a preliminary planning screen, not a design approval, irrigation audit, pump curve analysis or distribution-uniformity test.

Safety and review boundary. Use current manufacturer data and local requirements. Isolate electrical and pressurized equipment before service; use qualified help for backflow, pump controls and buried piping.