What this tool does

Makes the single-duty-condition screen explicit and links onward to TDH and pump curve work.

When to use it

Use only after a current pump curve or manufacturer duty condition is available.

Inputs and supported units

Each labelled field explains the quantity it expects. Unit-system changes convert existing numeric entries once and keep calculations on a single SI internal basis. Supported shared units include L/min and GPM, metres and feet, kPa and psi, millimetres and inches, kW and hp, and °C and °F as relevant.

Calculation or decision method

Required head = operating pressure head + elevation + pipe/valve loss; reserve applies to both flow and head screen.

How to interpret the result

Read the primary result with the supporting breakdown and warning. A plausible number is not evidence that every input, operating case or design constraint has been included.

Worked example

100 L/min at 60 m against an 80 L/min, 200 kPa zone with 10 m rise and 5 m loss is a Match with 10% reserve.

Assumptions

Entered measurements represent the same operating condition. Calculations use unrounded SI values and convert only for display.

Limitations

This is a preliminary planning screen, not a design approval, irrigation audit, pump curve analysis or distribution-uniformity test.

Safety and review boundary. Use current manufacturer data and local requirements. Isolate electrical and pressurized equipment before service; use qualified help for backflow, pump controls and buried piping.